2 – CLI Commands
Page 36 Airborne™ Product Family CLI Reference Guide 100-8005-101G
Quatech, Inc. Confidential
Command CLI Arguments Ln Description
pw-cfg <string> L3 Configures the Level 3 Password [31 characters, no spaces].
Default is cfg.
pw <string> L2 Configures the Level 2 Password [31 characters, no spaces].
Default is password.
logout L1 Return to Level 1.
restart L2 Restarts the Module firmware, reinitializing everything in the
system like a power cycle. All system configuration parameters
that have not been saved with the commit command will be
reinitialized to system defaults. All connections on the wireless
interface will be disconnected abruptly.
update L2 Updates the Module’s firmware using XMODEM. When using
terminal emulation software on a workstation as the serial host,
the terminal emulation software may prompt the user for the
filename to proceed. However, if used in an embedded system,
the XMODEM protocol will complete the transaction. Please see
“Data Bridging with XMODEM Guidelines” for more details.
After the update is completed, the Module restarts automatically.
Execute this command from the serial interface, with hardware
handshake enabled (not soft handshake).
time L2 Reports the number of seconds that the Module has been
operational. The accuracy of the internal timer is not guaranteed
when power modes are active.
reset L3 Restores all system configurations to the OEM defaults. This
has the same effect as using the “factory reset” button at power-
up.
2.2.9 I/O Commands — WLN ONLY
Command CLI Arguments Ln Description
io-read
e | f<portid>
L2 Reads the digital I/O port.
<port id> = a bit number from 0-7.
Returns the state of the I/O port.
Example: io-read e4
io-write
e | g<portid> <num>
L2 Writes a value to digital I/O port <num>.
<portid> = a bit number from 0-7 (or as allowed by the Signal
Assignments tables in the Airborne™ Wireless LAN
Node Module Data Book), if the direction has been
set as output.
<num> = 0 or 1.
Writing to a bit position that has been configured as an input
has no effect. Writing to port G3 has no effect.
io-dir-e [integer] L2 Sets the direction of port E I/O bits to input or output.
8 bits
Bit setting of 1 = Input, 0 = Output.
Bits 3-0 = don’t care
Bits 7-4 = must be 0 or 1
Default is all inputs. Requires restart to take effect.