Quatech CompactFlash Card User’s Manual SSCF-100 / SSCFR-100
- 7 -
5.2 ELECTRICAL
All figures quoted are typical parameters @ 25°C
RS-232 SIGNALS: Typical output level ±5.5V (open circuit voltages)
ESD PROTECTION: All RS-232 signal lines on the SSCF-100 / SSCFR-100 card are
protected against electrostatic discharge (ESD)
15kv - human body model
8kv - IEC1000-4-2, contact discharge
15kv - IEC1000-4-2, air-gap discharge
UART CLOCK SPEED: x1: UART CLOCK is 1.8432MHz ->115.2KBaud max
x8: UART CLOCK is 14.7456MHz->921.6KBaud max
5.3 POWER CONSUMPTION
All figures quoted are typical parameters @ 25°C
VCC CURRENT: 20mA typical @ 5V, 13mA typical @ 3.3V
IN STANDBY MODE: 14mA typical @ 5V, 5mA typical @ 3.3V
5.4 MECHANICAL
CARD MASS: 10g typical.
FORM FACTOR: 36.4mm x 42.8mm x 3.3 mm overall card size
SSCF-100 CABLE: Detachable 300mm cable with DB-9 male connector
SSCFR-100 CABLE: Attached 3.9mm thick cable protrudes 10.3mm from the back edge
of the card. The oval cable measures approx. 7mm x 1.7mm with
shield and 9x 7/0.1mm conductors.
5.5 ENVIRONMENTAL
HUMIDITY: <80% non-condensing
TEMP: 0-50°C ambient