Quatech DSP-200/300 Bedienungsanleitung Seite 45

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 52
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 44
6.2 Half Duplex Operation
The DSP-200/300’s ports may be configured for either full duplex or half duplex operation. By
default, the RS-422/485 ports are configured for full duplex operation with the RS-422/485
output drivers always enabled.
In half duplex mode, the RS-422/485 transmitter may be enabled and disabled via the RTS
(request to send) or DTR (data terminal ready) signals. Both RTS and DTR are controlled
through the Modem Control Register of the 16750.
RS-422/485
Driver
RS-422/485
Driver
+
-
+
-
Data Out
Aux Out
Active Low
Output Enable
3 Options:
Half Duplex
16C550
-RTS
-DTR
NOTE:
One of these three options must be selected via
software configuration. Full duplex operation is
the default mode.
Full Duplex
MUX
Figure 11. RS-422/485 Driver Enable Options
If RTS is selected as the signal to enable the output drivers, setting 'bit 1' of the Modem Control
Register (to logic '1') will enable the output drivers and clearing 'bit 1' of the Modem Control
Register (to logic '0') will force the outputs into a high impedance state.
Similarly, if DTR is chosen as the signal to enable the output drivers setting 'bit 0' of the Modem
Control Register (to logic '1') will enable the output drivers and clearing 'bit 0' of the Modem
Control Register (to logic '0') will force the outputs into a high impedance state.
Hardware Information 6-3
Seitenansicht 44
1 2 ... 40 41 42 43 44 45 46 47 48 49 50 51 52

Kommentare zu diesen Handbüchern

Keine Kommentare